Seismic Performance of Existing Building Retrofitted with VSL-Gensui Damper

Authors

  • Pamuda Pudjisuryadi Faculty of Civil Engineering and Planning, Civil Engineering Department, Petra Christian University, Jl. Siwalankerto 121-131, Surabaya 60236, INDONESIA
  • Benjamin Lumantarna Faculty of Civil Engineering and Planning, Civil Engineering Department, Petra Christian University, Jl. Siwalankerto 121-131, Surabaya 60236, INDONESIA
  • Tjhai Ferlinda Hermawan Faculty of Civil Engineering and Planning, Civil Engineering Department, Petra Christian University, Jl. Siwalankerto 121-131, Surabaya 60236, INDONESIA
  • Teddy Tirta Gunawan Faculty of Civil Engineering and Planning, Civil Engineering Department, Petra Christian University, Jl. Siwalankerto 121-131, Surabaya 60236, INDONESIA

:

https://doi.org/10.9744/ced.20.2.86-90

Keywords:

Displacement, nonlinear time history, PPTIUG 1983, story drift, VSL-Gensui Damper.

Abstract

Buildings designed using older code should be checked against the higher demand required by newer code. In this study, performance of Building T of Petra Christian University, Surabaya, Indonesia, which was designed with older Indonesian Seismic Code (PPTGIUG 1983) is investigated. The effectiveness of VSL-Gensui Damper application is also investigated as an effort to enhance the performance of the building. Nonlinear time history analysis was conducted to analyze the building. Spectrum consistent ground acceleration generated from El Centro 18 May 1940 North-South component in accordance to current seismic code was used for analysis. The result shows that the existing building cannot resist the demand specified by current code (SNI 1726:2012) as some frame element failures are detected. The performance is greatly enhanced after installation of VSL-Gensui Dampers. Roof story drift and displacement decreased as much as 9% and 14%, respectively as compared to existing building, and structural element failures were no longer observed.

References

Lumantarna, B., Pengantar Analisa Dinamis dan Gempa, Lembaga Penelitian dan Pengabdian kepada Masyarakat Universitas Kristen Petra, Surabaya, 2000. (in Indonesian).

PPTGIUG 1983, Peraturan Perencanaan Tahan Gempa Indonesia Untuk Gedung, Ditjen Cipta Karya Direktorat Penyelidikan Masalah Bangunan, 1983. (in Indonesian).

SNI 1726-2012, Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Non Gedung, Badan Standardisasi Nasional, 2012. (In Indonesian).

Computers & Structures, Inc., CSI Analysis Reference Manual, Berkeley, California, USA, 2016.

FEMA 356-2000, Pre Standard and Commentary for the Seismic Rehabilitation of Buildings, American Society of Civil Engineers, 2000.

ACMC 2001, Asian Concrete Model Code Level 1 & 2 Documents, International Committee on Concrete Model Code for Asia, 2001.

Susanto, A., Non-Linear Time History Seismic Analysis with VSL Gensui Dampers in ETABS, VSL Hongkong Limited, Hongkong, 2011.

Khan, W, Akhtar, S., and Hussain, A., Non-Linear Time History Analysis of Tall Structure for Seismic Load Using Damper, International Journal of Scientific and Research Publications, 4(1-5), 2014.

Montejo, L.A. and Kowalsky, M.J., CUMBIA – Set of Codes for the Analysis of Reinforced Concrete Members, North Carolina State University, Raleigh, 2007.

Downloads

Published

2018-10-08

How to Cite

Pudjisuryadi, P., Lumantarna, B., Hermawan, T. F., & Gunawan, T. T. (2018). Seismic Performance of Existing Building Retrofitted with VSL-Gensui Damper. Civil Engineering Dimension, 20(2), 86-90. https://doi.org/10.9744/ced.20.2.86-90

Most read articles by the same author(s)

<< < 1 2 3 > >>