Performance of an Existing Reinforced Concrete Building Designed in Accordance to Older Indonesian Seismic Code: A Case Study for a Hotel in Kupang, Indonesia

Authors

  • Pamuda Pudjisuryadi
  • Benjamin Lumantarna
  • Ryan Setiawan
  • Christian Handoko

:

https://doi.org/10.9744/ced.20.1.35-40

Keywords:

Indonesian seismic code, non-linear time history analysis, reinforced concrete, seismic performance.

Abstract

The recent seismic code SNI 1726-2012 is significantly different compared to the older code SNI 1726-2002. The seismic hazard map was significantly changed and the level of maximum considered earthquake was significantly increased. Therefore, buildings designed according to outdated code may not resist the higher demand required by newer code. In this study, seismic performance of Hotel X in Kupang, Indonesia which was designed based on SNI-1726-2002 is investigated. The structure was analyzed using Nonlinear Time History Analysis. The seismic load used was a spectrum consistent ground acceleration generated from El-Centro 18 May 1940 North-South component in accordance to SNI 1726-2012. The results show that Hotel X can resist maximum considered earthquake required by SNI 1726-2012. The maximum drift ratio is 0.81% which is lower than the limit set by FEMA 356-2000 (2%). Plastic hinge damage level is also lower than the allowance in ACMC 2001.

References

SNI-1726-2002, Standar Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung, Pusat Penelitian dan Pengembangan Teknologi Permukiman, 2002, (In Indonesian).

SNI 1726-2012, Tata Cara Perencanaan Ketahanan Gempa untuk Struktur Bangunan Gedung dan Non Gedung, Badan Standardisasi Nasional, 2012, (In Indonesian).

SNI 2847:2013, Persyaratan Beton Struktural untuk Bangunan Gedung, Badan Standardisasi Nasional, 2013, (In Indonesian).

RSNI-03-2847-2002, Tata Cara Perhitungan Struktur Beton untuk Bangunan Gedung, Badan Standardisasi Nasional, 2002, (In Indonesian).

Computers & Structures, Inc., CSI Analysis Reference Manual, Berkeley, California, USA, 2016.

Montejo, L.A. and Kowalsky, M.J., CUMBIA–Set of Codes for the Analysis of Reinforced Concrete Members, North Carolina State University, Raleigh, 2007.

FEMA 356-2000, Pre Standard and Commentary for the Seismic Rehabilitation of Buildings, American Society of Civil Engineers, 2000.

ACMC 2001, Asian Concrete Model Code Level 1 & 2 Documents, International Committee on Concrete Model Code for Asia, 2001.

Downloads

Published

2018-04-07

How to Cite

Pudjisuryadi, P., Lumantarna, B., Setiawan, R., & Handoko, C. (2018). Performance of an Existing Reinforced Concrete Building Designed in Accordance to Older Indonesian Seismic Code: A Case Study for a Hotel in Kupang, Indonesia. Civil Engineering Dimension, 20(1), 35-40. https://doi.org/10.9744/ced.20.1.35-40

Issue

Section

Articles

Most read articles by the same author(s)

1 2 3 > >>